|
| LM392 |
|
||
|
TI |
|
3 page
www.ti.com Absolute Maximum Ratings (1) Recommended Operating Conditions LOW-POWER OPERATIONAL AMPLIFIER AND VOLTAGE COMPARATOR SLOS466 – JANUARY 2006 over operating free-air temperature range (unless otherwise noted) MIN MAX UNIT Single supply 32 V+ Supply voltage V Dual supply ±16 VID Differential input voltage 32 V VIN Input voltage range –0.3 32 V II Input current(2) VIN < –0.3 V 50 mA tshort Duration of output short circuit to ground(3) Continuous D package 97 θ JA Package thermal impedance, junction to free air(4) DGK package 172 °C/W P package 84 Tlead Lead temperature during soldering 10 s maximum 260 °C Tstg Storage temperature range –65 150 °C (1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. (2) This input current exists only when the voltage at any of the input leads is driven negative. It is due to the collector-base junction of the input PNP transistors becoming forward biased and thereby acting as input diode clamps. In addition to this diode action, there is also lateral NPN parasitic transistor action on the device. This transistor action can cause the output voltages of the amplifiers to go to the V+ voltage level (or to ground for a large overdrive) for the time duration that an input is driven negative. This is not destructive, and normal output states reestablish when the input voltage, which was negative, again returns to a value greater than –0.3 V (at 25°C). (3) Short circuits from the output to V+ can cause excessive heating and eventual destruction. When considering short circuits to ground, the maximum output current is approximately 40 mA for the operational amplifier and 30 mA for the comparator, independent of the magnitude of V+. At values of supply voltage in excess of 15 V, continuous short circuits can exceed the power dissipation ratings and cause eventual destruction. (4) Package thermal impedance is calculated in accordance with JESD 51-7. MIN MAX UNIT Single supply 3 32 V+ Supply voltage V Dual supply ±1.5 ±16 TA Operating free-air temperature 0 70 °C 3 |
|
Enlace URL |
Patrocinador de Alldatasheet |
|
| ¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Favorito | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved© Alldatasheet.com 2003 - 2012 |
| Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com | Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl |