1 / 4 page SS-PD and SS-PDR CS-2463 10/21/04 Page 1 of 4 Features • Air velocity rating from 100 to 4,000 feet per minute (0.5 to 20.32 m/sec.). • Patented telescopic sampling tube. • Easily accessible code wheels for addressing detector. • Outside mounting tabs. • Mounts to round or rectangular ducts from 1’ to 12’ (0.3 to 3.7 meters) wide. • Transparent cover for conve- nient visual inspection. Listings Listings and approvals below apply to the SS-PD and SS- PDR Intelligent Low-Flow Photoelectric Duct Smoke Detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: file S1115. • CSFM approved: file 3240-1288:167. • MEA approved: file 384-02-E Vol. III. SS-PD and SS-PDR Intelligent Low-Flow Photoelectric Duct Smoke Detectors Description The Gamewell SS-PD and SS-PDR Intelligent Low-Flow Photoelectric Smoke Duct Detectors provide low- flow technology that enables duct smoke detection throughout a broad range of airflow environments in HVAC applications. The low-flow technology can detect smoke at air speed veloci- ties of 100 feet per minute (0.5 m/sec.) or greater, while continuing the same reliable performance to 4,000 feet per minute (20.32 m/sec.). The intelligent low-flow duct detectors sample air cur- rents passing through a duct and gives dependable performance for shutdown SS-PDR Applications Duct smoke detectors have specific limitations, they are: • NOT a substitute for open area smoke detectors. • NOT a substitute for early warning detection. • NOT a replacement for a building’s regular fire detection system. Please call Gamewell for a copy of System Sensor’s application guide, Proper Use of Smoke Detectors in Duct Applications, (A05-1004-00). Installation Wiring: For signal wiring (the wiring between detectors or from detectors to auxil- iary devices), it is recommended that single conductor wire be no smaller than 18 AWG (0.75 mm²). The duct smoke detector terminals accommodate wire sizes up to 12 AWG (3.25 mm²). Flexible conduit is recommended for the last foot (30.48 cm) of conduit; solid conduit connections may be used if desired. Smoke detectors and alarm system control panels have specifications for Signal- ing Line Circuit (SLC) wiring. Consult the control panel specifications for wiring requirements before wiring the detector loop. The SS-PD and SS-PDR detectors are designed for ease of wiring; their housing provides a terminal strip with clamp- ing plates. LED Features: If programmed with the system control panel, two LEDs on each duct smoke detector light to provide local visible indication. SS-PD of fans, blowers, and air conditioning systems, preventing the spread of toxic smoke an fire gases through the protected area. The SS-PD and SS-PDR provide a remote alarm output for use with auxiliary devices such as the RA400 remote LED annunciator, as well as remote test capa- bility with the RTS451 or RTS451KEY Remote Test Stations. The SS-PD is a photoelectric duct detector with SmartScanTM protocol. The SS- PDR additionally incorporates a relay. |
Número de pieza similar - SS-PD |
|
Descripción similar - SS-PD |
|
|
Enlace URL |
Política de Privacidad |
ALLDATASHEET.ES |
¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |