Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
TMP006_1107 Datasheet(PDF) 4 Page - Texas Instruments |
|
TMP006_1107 Datasheet(HTML) 4 Page - Texas Instruments |
4 / 21 page TMP006 SBOS518A – MAY 2011 – REVISED JULY 2011 www.ti.com ELECTRICAL CHARACTERISTICS At TA = +25°C, V+ = 3.3 V, and conversion time = 1 sec, unless otherwise specified. TMP006 PARAMETER TEST CONDITIONS MIN TYP MAX UNIT OUTPUT ERROR TA = 0°C to +60°C, V+ = 2.2 V to 5.5 V ±0.5 ±1 °C Ambient temperature sensor TA = –40°C to +125°C, V+ = 2.2 V to 5.5 V ±0.5 ±1.5 °C Power-supply rejection ratio PSRR 0.1 °C/V Sensor voltage TObject = +40°C to +60°C, TA = 0°C to +60°C 7 μV/°C TA = +20°C to +60°C, Calculate object temperature(1) ±1 ±3 °C TObject – TA = –10°C to +30°C, V+ = 2.2 V to 5.5 V Field of view 50% responsivity 90 Degrees TEMPERATURE MEASUREMENT CR2 = 0, CR1 = 0, CR0 = 0 0.25 Seconds CR2 = 0, CR1 = 0, CR0 = 1 0.5 Seconds Conversion time CR2 = 0, CR1 = 1, CR0 = 0 1 Seconds CR2 = 0, CR1 = 1, CR0 = 1 2 Seconds CR2 = 1, CR1 = 0, CR0 = 0 4 Seconds Resolution Local temperature sensor 0.03125 °C Thermopile sensor resolution 156.25 nV SMBus COMPATIBLE INTERFACE Logic input high voltage (SCL, SDA) VIH 2.1 V Logic input low voltage (SCL, SDA) VIL 0.8 V Hysteresis 100 mV Output low voltage (SDA) VOL IOUT = 6 mA 0.15 0.4 V Output low sink current (SDA) 6 mA Logic input current Forced to 0.4 V –1 +1 µA Input capacitance (SCL, SDA, A0, A1) 3 pF Clock frequency 0.001 3.4 MHz Interface timeout 25 30 35 ms DIGITAL OUTPUTS Output low voltage (DRDY pin) VOL IOUT = 4 mA 0.15 0.4 V High-level output leakage current IOH VOUT = VDD 0.1 1 µA Output low sink current (DRDY) Forced to 0.4 V 4 mA POWER SUPPLY Power-on reset V+ T = –40°C to +125°C 1.6 V Specified voltage range V+ T = –40°C to +125°C 2.2 5.5 V Continuous conversion; see Table 9 240 325 µA Serial bus inactive, shutdown mode 0.5 1.0 µA Quiescent current IQ Serial bus active, fS = 400 kHz, 90 µA shutdown mode TEMPERATURE RANGE Specified range –40 +125 °C Storage range –65 +150 °C (1) This parameter is tested in a fully-settled setup with no transients, in front of an ideal black body, with specified layout constraints, and after system calibration. 4 Submit Documentation Feedback Copyright © 2011, Texas Instruments Incorporated Product Folder Link(s): TMP006 |
Número de pieza similar - TMP006_1107 |
|
Descripción similar - TMP006_1107 |
|
|
Enlace URL |
Política de Privacidad |
ALLDATASHEET.ES |
¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |