Back Button AD598A Datasheet HTML 2Page - Analog Devices AD598A Datasheet HTML 3Page - Analog Devices AD598A Datasheet HTML 4Page - Analog Devices AD598A Datasheet HTML 5Page - Analog Devices AD598A Datasheet HTML 6Page - Analog Devices AD598A Datasheet HTML 7Page - Analog Devices AD598A Datasheet HTML 8Page - Analog Devices AD598A Datasheet HTML 9Page - Analog Devices AD598A Datasheet HTML 10Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 16 page
background image
AD598
REV. A
–6–
DESIGN PROCEDURE
DUAL SUPPLY OPERATION
Figure 7 shows the connection method with dual
±15 volt power
supplies and a Schaevitz E100 LVDT. This design procedure
can be used to select component values for other LVDTs as
well. The procedure is outlined in Steps 1 through 10 as follows:
1. Determine the mechanical bandwidth required for LVDT
position measurement subsystem, fSUBSYSTEM. For this
example, assume fSUBSYSTEM = 250 Hz.
2. Select minimum LVDT excitation frequency, approximately
10
× f
SUBSYSTEM. Therefore, let excitation frequency = 2.5 kHz.
3. Select a suitable LVDT that will operate with an excitation
frequency of 2.5 kHz. The Schaevitz E100, for instance, will
operate over a range of 50 Hz to 10 kHz and is an eligible
candidate for this example.
4. Determine the sum of LVDT secondary voltages VA and VB.
Energize the LVDT at its typical drive level VPRI as shown in
the manufacturer’s data sheet (3 V rms for the E100). Set the
core displacement to its center position where VA = VB. Mea-
sure these values and compute their sum VA+VB. For the
E100, VA+VB = 2.70 V rms. This calculation will be used
later in determining AD598 output voltage.
5. Determine optimum LVDT excitation voltage, VEXC. With
the LVDT energized at its typical drive level VPRI, set the
core displacement to its mechanical full-scale position and
measure the output VSEC of whichever secondary produces
the largest signal. Compute LVDT voltage transformation
ratio, VTR.
VTR = VPRI/VSEC
For the E100, VSEC = 1.71 V rms for VPRI = 3 V rms.
VTR = 1.75.
The AD598 signal input, VSEC, should be in the range of
1 V rms to 3.5 V rms for maximum AD598 linearity and
minimum noise susceptibility. Select VSEC = 3 V rms. There-
fore, LVDT excitation voltage VEXC should be:
VEXC = VSEC
× VTR = 3 × 1.75 = 5.25 V rms
Check the power supply voltages by verifying that the peak
values of VA and VB are at least 2.5 volts less than the volt-
ages at +VS and –VS.
6. Referring to Figure 7, for VS =
±15 V, select the value of the
amplitude determining component R1 as shown by the curve
in Figure 8.
7. Select excitation frequency determining component C1.
C1 = 35
µF Hz/f
EXCITATION
30
20
10
0
0.01
0.1
1
10
100
1000
R1 – k
Vrms
Figure 8. Excitation Voltage VEXC vs. R1
EXC 1
EXC 2
LEV 1
LEV 2
FREQ 1
FREQ 2
B1 FILT
B2 FILT
OFFSET 1
OFFSET 2
SIG REF
SIG OUT
FEEDBACK
OUT FILT
A1 FILT
A2 FILT
R1
C1
C2
AD598
C3
R2
C4
LVDT
SCHAEVITZ E100
R3
R4
6.8
µF
0.1
µF
0.1
µF
6.8
µF
–15V
SIGNAL
REFERENCE
15V
+
–VS
R
L
VOUT
+VS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
16
15
17
18
19
20
NOTE
FOR C1, C2, C3 AND C4 MYLAR
CAPACITORS ARE
RECOMMENDED. CERAMIC
CAPACITORS MAY BE
SUBSTITUTED. FOR R2, R3 AND
R4 USE STANDARD 1%
RESISTORS.
V
A
V
B
V
B
V
A
Figure 7. Interconnection Diagram for Dual Supply Operation


Número de pieza similar - AD598A

Fabricante ElectrónicoNo. de piezaDatasheetDescripción Electrónicos
logo
Analog Devices
AD598 AD-AD598_15 Datasheet
556Kb / 16P
   LVDT Signal Conditioner
REV. A
More results

Descripción similar - AD598A

Fabricante ElectrónicoNo. de piezaDatasheetDescripción Electrónicos
logo
NXP Semiconductors
NE5521 PHILIPS-NE5521 Datasheet
69Kb / 5P
   LVDT signal conditioner
August 31, 1994
logo
Analog Devices
AD598 AD-AD598_15 Datasheet
556Kb / 16P
   LVDT Signal Conditioner
REV. A
AD698 AD-AD698 Datasheet
228Kb / 12P
   Universal LVDT Signal Conditioner
REV. B
AD698 AD-AD698_15 Datasheet
235Kb / 12P
   Universal LVDT Signal Conditioner
REV. B
AD698APZ AD-AD698APZ Datasheet
235Kb / 12P
   Universal LVDT Signal Conditioner
REV. B
logo
Vitesse Semiconductor C...
VSC7104 VITESSE-VSC7104 Datasheet
461Kb / 2P
   Quad Signal Conditioner, Octal Signal Conditioner
logo
TE Connectivity Ltd
LDM-1000 TEC-LDM-1000 Datasheet
140Kb / 3P
   LVDT/RVDT Signal Conditioning Module
logo
Festo Corporation.
544216 FESTO-544216 Datasheet
85Kb / 1P
   Signal conditioner
544218 FESTO-544218 Datasheet
87Kb / 1P
   Signal conditioner
544221 FESTO-544221 Datasheet
88Kb / 1P
   Signal conditioner
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Descarga

Go To PDF Page


Enlace URL




Política de Privacidad
ALLDATASHEET.ES
¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com