10 / 18 page CD74ACT297 DIGITAL PHASE-LOCKED LOOP SCHS297D – AUGUST 1998 – REVISED JUNE 2002 10 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 switching characteristics over recommended operating free-air temperature range, CL = 50 pF (unless otherwise noted) PARAMETER FROM TO TA = 25°C MIN MAX UNIT PARAMETER (INPUT) (OUTPUT) MIN TYP MAX MIN MAX UNIT f K CLK I/D OUT 55 45 MHz fmax I/D CLK I/D OUT 40 35 MHz tPLH I/D CLK I/D OUT 19 24 ns tPHL I/D CLK I/D OUT 19 24 ns tPHL φA2 ECPD OUT 24 30 ns tPLH φA1 XORPD OUT 17 22 ns tPHL φA1 XORPD OUT 17 22 ns tPLH φB XORPD OUT 17 22 ns tPHL φB XORPD OUT 17 22 ns tPLH φB ECPD OUT 24 30 ns |
Número de pieza similar - CD74ACT297_14 |
|
Descripción similar - CD74ACT297_14 |
|
|
Enlace URL |
Política de Privacidad |
ALLDATASHEET.ES |
¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |