Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
M9300A Datasheet(PDF) 5 Page - Keysight Technologies |
|
M9300A Datasheet(HTML) 5 Page - Keysight Technologies |
5 / 29 page 05 | Keysight | M9381A PXIe Vector Signal Generator – Data Sheet Technical Specifications and Characteristics Definitions for specifications Temperatures referred to in this document are defined as follows: – Full temperature range = Individual module temperature of ≤ 75 °C as reported by the module, and environment temperature of 0 to 55 °C. – Controlled temperature range = Individual module temperature of ≤ 55 °C as reported by the module, and environment temperature of 20 to 30 °C. Specifications describe the warranted performance of calibrated instruments. Data represented in this document are specifications under the following conditions unless otherwise noted. – Calibrated instruments have been stored for a minimum of 2 hours within the full temperature range – 45 minute warm-up time – Calibration cycle maintained – When used with Keysight M9300A frequency reference and Keysight interconnect cables Characteristics describe product performance that is useful in the application of the product. Characteristics are often referred to as Typical or Nominal values and are italicized. – Typical describes characteristic performance, which 80% of instruments will meet when operated within the controlled temperature range. – Nominal describes representative performance that is useful in the application of the product when operated within the controlled temperature range. Recommended best practices in use – Use slot blockers and EMC filler panels in empty module slots to ensure proper operating temperatures. Keysight chassis and slot blockers optimize module temperature performance and reliability of test. – Set chassis fan to high at environmental temperatures above 45 °C. – Maintain temperature stability for best multi-channel phase coherence – Set chassis fans to maximum – Maintain stable ambient temperature – Perform warm-up with session open and representative waveform running Additional information – Specifications use the normal PLL mode setting, unless otherwise stated. Narrow loop bandwidth refers to specifications using the best wide offset PLL mode setting AGM938X_VAL_SYNTHESIZER_PLL_MODE_BEST_WIDE_ OFFSET, available in the M938x Vector Signal Generator/CW Source Instrument Drivers versions 1.2.300 and later. – Performance described in this document applies for mod- ule temperature within ± 5 degrees of IQ alignment, unless otherwise noted. – When configured for multi-channel, phase-coherent operation (shared synthesizer configuration), instrument level warranted specifications only apply to the M9381A which was previously calibrated with the M9301A synthesizer, showing a valid calibration indicator. For all other M9381A channels, specifications revert to typical performance. If using an ex- ternal LO distribution unit, such as the V2802A LO distribu- tion network, specifications for all M9381A channels revert to typical performance. – All graphs contain measured data from one unit and are representative of product performance within the controlled temperature range unless otherwise noted. – The specifications contained in this document are subject to change . |
Número de pieza similar - M9300A |
|
Descripción similar - M9300A |
|
|
Enlace URL |
Política de Privacidad |
ALLDATASHEET.ES |
¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |