2
A6150
Absolute Maximum Ratings
Parameter
Symbol
Conditions
Continuous voltage at INPUT
to VSS
VINPUT
-0.3 to + 30 V
Transients on INPUT for
t < 100 ms and duty cycle 1%
VTRANS
up to + 60 V
Reverse supply voltage on INPUT
VREV
- 20 V
Max. voltage at any signal pin
VMAX
OUTPUT + 0.3 V
Min. voltage at any signal pin
VMIN
VSS – 0.3 V
Storage temperature
TSTO
-65 to + 150 °C
Electrostatic discharge max. to
MIL-STD-883C method 3015
VSmax
1000 V
Max. soldering conditions
TSmax
250 °C x 10 s
Table 1
Stresses above these listed maximum ratings may cause
permanent damage to the device. Exposure be-
yond specified operating conditions may affect device
reliability or cause malfunction.
Handling Procedures
This device has built-in protection against high static
voltages or electric fields; however, anti-static precau-
tions must be taken as for any other CMOS component.
Unless otherwise specified, proper operation can only
occur when all terminal voltages are kept within the
supply voltage range. At any time, all inputs must be tied
to a defined logic voltage level.
Operating Conditions
Parameter
Symbol
Min. Typ. Max. Units
Operating junction
temperature 1)
TJ
-40
+125
°C
INPUT voltage 2)
VINPUT
2.3
26
V
OUTPUT voltage 2) 3)
VOUTPUT
1.2
V
RES & EN guaranteed 4) VOUTPUT
1.2
V
OUTPUT current 5)
IOUTPUT
100
mA
Comparator input
voltage
VIN
0VOUTPUT
V
RC-oscillator
programming
R
10
1000
kΩ
Thermal resistance from
junction to ambient 6)
-DIP8
Rth(j-a)
105
°C/W
-SO8
Rth(j-a)
160
°C/W
Table 2
1) The maximum operating temperature is confirmed by
sampling at initial device qualification. In production, all
devices are tested at +85 °C. On request devices tested at
+125 °C can be supplied.
2) Full operation quaranteed. To achieve the load regulation
specified in Table 3 a 22 µF capacitor or greater is
required on the INPUT, see Fig. 18. The 22 µF must have
an effective resistance ≤ 5 Ω and a resonant frequency
above 500 kHz.
3) A 10 µF load capacitor and a 100 nF decoupling capacitor
are required on the regulator OUTPUT for stability. The
10 µF must have an effective series resistance of ≤ 5 Ω and
a resonant frequency above 500 kHz.
4) RES and EN (EN only for version A0) must be pulled up
externally to VOUTPUT even if they are unused. (Note: RES
and EN are used as inputs by EM test).
5) The OUTPUT current will not apply for all possible
combinations of input voltage and output current.
Combinations that would require the A6150 to work above
the maximum junction temperature (+125 °C) must be
avoided.
6) The thermal resistance specified assumes the package is
soldered to a PCB.