7 / 63 page
IBIS4-6600
Datasheet
Cypress Semiconductor Corporation
3901 North First Street
San Jose, CA 95134
408-943-2600
Contact: info@Fillfactory.com
Document #: 38-05708 Rev.**(Revision 1.3 )
Page 7 of 63
Parameter
Specification
Remarks
Spectral
sensitivity range
400 – 1000 nm
Optical cross talk
15%
4%
To the first neighboring pixel.
To the second neighboring pixel.
Power
dissipation
190 mWatt
Typical (with ADC’s).
2.2.2 Spectral response curve
0
0.02
0.04
0.06
0.08
0.1
0.12
0.14
400
500
600
700
800
900
1000
Wavelenght [nm]
QE 10%
QE 20%
QE 30%
Figure 1: Spectral response curve
Figure 1 shows the spectral response characteristic. The curve is measured directly on
the pixels. It includes effects of non-sensitive areas in the pixel, e.g. interconnection
lines. The sensor is light sensitive between 400 and 1000 nm. The peak QE * FF is
22.5% approximately between 500 and 700 nm. In view of a fill factor of 50%, the
QE is thus close to 50% between 500 and 700 nm.