Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
6N137-000E Datasheet(PDF) 8 Page - AVAGO TECHNOLOGIES LIMITED |
|
6N137-000E Datasheet(HTML) 8 Page - AVAGO TECHNOLOGIES LIMITED |
8 / 21 page 8 Insulation and Safety Related Specifications 8-pin DIP Widebody (300 Mil) SO-8 (400 Mil) Parameter Symbol Value Value Value Unit Conditions Minimum External L(101) 7.1 4.9 9.6 mm Measured from input terminals Air Gap to output terminals, shortest (External Clearance) distance through air. Minimum External L(102) 7.4 4.8 10.0 mm Measured from input terminals Tracking to output terminals, shortest (External Creepage) distance path along body. Minimum Internal 0.08 0.08 1.0 mm Through insulation distance, Plastic Gap conductor to conductor, usually (Internal Clearance) the direct distance between the photoemitter and photodetector inside the optocoupler cavity. Minimum Internal NA NA 4.0 mm Measured from input terminals Tracking to output terminals, along (Internal Creepage) internal cavity. Tracking Resistance CTI 200 200 200 V DIN IEC 112/VDE 0303 Part 1 (Comparative Tracking Index) Isolation Group IIIa IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1) Option 300 - surface mount classification is Class A in accordance with CECC 00802. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (HCPL-06xx Option 060 Only) Description Symbol Characteristic Unit Installation classification per DIN VDE 0110, Table 1 for rated mains voltage ≤ 150 V rms I-IV for rated mains voltage ≤ 300 V rms I-IV for rated mains voltage ≤ 600 V rms I-III Climatic Classification 40/85/21 Pollution Degree (DIN VDE 0110/39) 2 Maximum Working Insulation Voltage V IORM 567 V peak Input-to-Output Test Voltage, Method b* V IORM x 1.875 = VPR, 100% Production Test with tm = 1 sec, V PR 1063 V peak Partial Discharge < 5 pC Input-to-Output Test Voltage, Method a* V IORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec, V PR 907 V peak Partial Discharge < 5 pC Highest Allowable Overvoltage (Transient Overvoltage, t ini = 60 sec) V IOTM 6000 V peak Safety Limiting Values (Maximum values allowed in the event of a failure) Case Temperature T S 150 °C Input Current** I S,INPUT 150 mA Output Power** P S,OUTPUT 600 mW Insulation Resistance at T S, VIO = 500 V R S ≥109 Ω *Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a detailed description. Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application. |
Número de pieza similar - 6N137-000E |
|
Descripción similar - 6N137-000E |
|
|
Enlace URL |
Política de Privacidad |
ALLDATASHEET.ES |
¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |