Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
ADUM5201ARWZ-RL Datasheet(PDF) 10 Page - Analog Devices |
|
ADUM5201ARWZ-RL Datasheet(HTML) 10 Page - Analog Devices |
10 / 28 page ADuM5200/ADuM5201/ADuM5202 Data Sheet Rev. B | Page 10 of 28 IEC 60747-5-2 (VDE 0884, PART 2):2003-01 INSULATION CHARACTERISTICS These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by the protective circuits. The asterisk (*) marking branded on the components designates IEC 60747-5-2 (VDE 0884, Part 2):2003-1 approval. Table 17. VDE Characteristics Description Conditions Symbol Characteristic Unit Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 150 V rms I to IV For Rated Mains Voltage ≤ 300 V rms I to III For Rated Mains Voltage ≤ 400 V rms I to II Climatic Classification 40/105/21 Pollution Degree per DIN VDE 0110, Table 1 2 Maximum Working Insulation Voltage V IORM 560 V PEAK Input-to-Output Test Voltage, Method b1 V IORM × 1.875 = Vpd (m), 100% production test, tini = tm = 1 sec, partial discharge < 5 pC V pd (m) 1050 V PEAK Input-to-Output Test Voltage, Method a After Environmental Tests Subgroup 1 V IORM × 1.5 = Vpd (m), tini = 60 sec, tm = 10 sec, partial discharge < 5 pC V pd (m) 840 V PEAK After Input and/or Safety Test Subgroup 2 and Subgroup 3 V IORM × 1.2 = Vpd (m), tini = 60 sec, tm = 10 sec, partial discharge < 5 pC V pd (m) 672 V PEAK Highest Allowable Overvoltage V IOTM 4000 V PEAK Withstand Isolation Voltage 1 minute withstand rating V ISO 2500 V RMS Surge Isolation Voltage V PEAK = 6 kV, 1.2 µs rise time, 50 µs, 50% fall time V IOSM 6000 V PEAK Safety Limiting Values Maximum value allowed in the event of a failure (see Figure 5) Case Temperature T S 150 °C Side 1 I DD1 Current I S1 555 mA Insulation Resistance at T S V IO = 500 V R S >109 Ω 0 100 200 300 400 500 600 0 50 100 150 200 AMBIENT TEMPERATURE (°C) Figure 5. Thermal Derating Curve, Dependence of Safety Limiting Values on Case Temperature, per DIN EN 60747-5-2 RECOMMENDED OPERATING CONDITIONS Table 18. Parameter Symbol Min Max Unit Operating Temperature1 T A −40 +105 °C Supply Voltages2 V DD1 @ VSEL = 0 V V DD1 3.0 5.5 V V DD1 @ VSEL = VISO V DD1 4.5 5.5 V 1 Operation at 105°C requires reduction of the maximum load current as specified in Table 19. 2 Each voltage is relative to its respective ground. |
Número de pieza similar - ADUM5201ARWZ-RL |
|
Descripción similar - ADUM5201ARWZ-RL |
|
|
Enlace URL |
Política de Privacidad |
ALLDATASHEET.ES |
¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |