Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
CS5.241 Datasheet(PDF) 11 Page - Red Lion Controls. Inc |
|
CS5.241 Datasheet(HTML) 11 Page - Red Lion Controls. Inc |
11 / 20 page CS5.241, CS5.241-C1, CS5.241-S1 C–Series 24V, 5A, SINGLE PHASE INPUT Dec. 2006 / Rev. 1.3 DS-CS5.241-EN All parameters are specified at 24V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 11/20 15. ENVIRONMENT Operational temperature -25°C to +70°C (-13°F to 158°F) reduce output power according Fig. 15-1 Output de-rating 1.6W/°C 45-60°C (113°F to 140°F), 3W/°C 60-70°C (140°F to 158°F), Storage temperature -40 to +85°C (-40°F to 185°F) storage and transportation Humidity 5 to 95% r.H. IEC 60068-2-30 Do not energize while condensation is present Vibration sinusoidal 2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g 2 hours / axis IEC 60068-2-6 Shock 30g 6ms, 20g 11ms 3 bumps / direction, 18 bumps in total IEC 60068-2-27 Altitude 0 to 6000m (0 to 20 000ft) Reduce output power or ambient temperature above 2000m sea level. Output de-rating (for altitude) 7.5W/1000m or 5°C/1000m above 2000m (6500ft), see Fig. 15-2 Over-voltage category III EN 50178, altitudes up to 2000m II Altitudes from 2000m to 6000m Degree of pollution 2 EN 50178, not conductive Fig. 15-1 Output current vs. ambient temp., Fig. 15-2 Output current vs. altitude, 24V 0 -25 0 20 40 70°C 1 2 3 4 5 6A 60 Ambient Temperature continuous short term Allowable Output Current at 24V 0 0 2000 4000 6000m 1 2 3 4 5 6A Altitude A... Tamb < 60°C B... Tamb < 50°C C... Tamb < 40°C C B A short term Allowable Output Current at 24V The ambient temperature is defined 2cm below the unit. 16. PROTECTION FEATURES Output protection Electronically protected against overload, no-load and short-circuits Output over-voltage protection typ. 35Vdc max. 39Vdc In case of an internal power supply defect, a redundant circuitry limits the maximum output voltage. The output shuts down and automatically attempts to restart. Output over-current protection electronically limited see Fig. 8-1 Degree of protection IP 20 EN/IEC 60529 Penetration protection > 3.5mm e.g. screws, small parts Over-temperature protection yes output shut-down with automatic restart Input transient protection MOV Metal Oxide Varistor Internal input fuse T4A H.B.C. not user replaceable Note: In case of a protection event, audible noise may occur. |
Número de pieza similar - CS5.241 |
|
Descripción similar - CS5.241 |
|
|
Enlace URL |
Política de Privacidad |
ALLDATASHEET.ES |
¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |