ADT7476 Datasheet(PDF) 9 Page - ON Semiconductor

No. de pieza ADT7476
Descripción Electrónicos  Remote Thermal Controller and Voltage Monitor
Download  68 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Fabricante Electrónico  ONSEMI [ON Semiconductor]
Página de inicio  http://www.onsemi.com
Logo ONSEMI - ON Semiconductor

ADT7476 Datasheet(HTML) 9 Page - ON Semiconductor

Back Button ADT7476_16 Datasheet HTML 5Page - ON Semiconductor ADT7476_16 Datasheet HTML 6Page - ON Semiconductor ADT7476_16 Datasheet HTML 7Page - ON Semiconductor ADT7476_16 Datasheet HTML 8Page - ON Semiconductor ADT7476_16 Datasheet HTML 9Page - ON Semiconductor ADT7476_16 Datasheet HTML 10Page - ON Semiconductor ADT7476_16 Datasheet HTML 11Page - ON Semiconductor ADT7476_16 Datasheet HTML 12Page - ON Semiconductor ADT7476_16 Datasheet HTML 13Page - ON Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 68 page
background image
ADT7476
www.onsemi.com
9
Serial Bus Interface
Control of the ADT7476 is carried out using the serial
system management bus (SMBus). The ADT7476 is
connected to this bus as a slave device, under the control of
a master controller. The ADT7476 has a 7-bit serial bus
address. When the device is powered up with Pin 13
(PWM3/ADDREN) high, the ADT7476 has a default
SMBus address of 0101110 or 0x2E. The read/write bit must
be added to get the 8-bit address. If more than one ADT7476
is to be used in a system, each ADT7476 is placed in ADDR
SELECT mode by strapping Pin 13 low on powerup. The
logic state of Pin 14 then determines the device’s SMBus
address. The logic of these pins is sampled on powerup.
The device address is sampled on powerup and latched on
the first valid SMBus transaction, more precisely on the
low-to-high transition at the beginning of the eighth SCL
pulse, when the serial bus address byte matches the selected
slave address. The selected slave address is chosen using the
ADDREN pin/ADDR SELECT pin. Any attempted
changes in the address have no effect after this.
Table 5. HARDWIRING THE ADT7476 SMBUS
DEVICE ADDRESS
Pin 13 State
Pin 14 State
Address
0
Low (10 k
W to GND)
0101100 (0x2C)
0
High (10 k
W Pullup)
0101101 (0x2D)
1
Don’t Care
0101110 (0x2E)
Figure 14. Default SMBus Address = 0x2E
ADDR SELECT
ADT7476
14
13
PWM3/
ADDREN
10 k
W
ADDRESS = 0x2E
VCC
Figure 15. SMBus Address = 0x2C (Pin 14 = 0)
ADDR SELECT
ADT7476
14
13
PWM3/
ADDREN
10 k
W
ADDRESS = 0x2C
Figure 16. SMBus Address = 0x2D (Pin 14 = 1)
ADDR SELECT
ADT7476
14
13
PWM3/
ADDR_EN
10 k
W
ADDRESS = 0x2D
VCC
Figure 17. Unpredictable SMBus Address if Pin 13
is Unconnected
DO NOT LEAVE ADDREN
UNCONNECTED! CAN CAUSE
UNPREDICTABLE ADDRESSES.
NOTE THAT IF THE ADT7476 IS PLACED INTO ADDR SELECT
MODE, PINS 13 AND 14 CANNOT BE USED AS THE ALTERNATE
FUNCTIONS (PWM3, TACH4/THERM) UNLESS THE CORRECT
CIRCUIT IS MUXED IN AT THE CORRECT TIME OR DESIGNED
TO HANDLE THESE DUAL FUNCTIONS.
CARE SHOULD BE TAKEN TO ENSURE THAT PIN 13
(PWM3/ADDREN) IS EITHER TIED HIGH OR LOW. LEAVING
PIN 13 FLOATING COULD CAUSE THE ADT7476 TO POWER UP
WITH AN UNEXPECTED ADDRESS.
ADDR SELECT
ADT7476
14
13
PWM3/
ADDREN
10 k
W
VCC
NC
The ability to make hardwired changes to the SMBus
slave address allows the user to avoid conflicts with other
devices sharing the same serial bus, for example, if more
than one ADT7476 is used in a system.
The serial bus protocol operates as follows:
1. The master initiates data transfer by establishing a
start condition, which is defined as a high-to-low
transition on the serial data line SDA while the
serial clock line SCL remains high. This indicates
that an address/data stream follows. All slave
peripherals connected to the serial bus respond to
the start condition and shift in the next eight bits,
consisting of a 7-bit address (MSB first), plus a
R/W bit, which determine the direction of the data
transfer, that is, whether data is written to or read
from the slave device.
The peripheral whose address corresponds to the
transmitted address responds by pulling the data
line low during the low period before the ninth
clock pulse, known as the acknowledge bit. All
other devices on the bus now remain idle while the
selected device waits for data to be read from or
written to it. If the R/W bit is a 0, the master writes
to the slave device. If the R/W bit is a 1, the master
reads from the slave device.
2. Data is sent over the serial bus in sequences of nine
clock pulses, eight bits of data followed by an
acknowledge bit from the slave device. Transitions
on the data line must occur during the low period of
the clock signal and remain stable during the high
period. A low-to-high transition, when the clock is
high, can be interpreted as a stop signal. The
number of data bytes transmitted over the serial bus
in a single read or write operation is limited only by
what the master and slave devices can handle.
3. When all data bytes have been read or written, stop
conditions are established. In write mode, the
master pulls the data line high during the 10th clock


Número de pieza similar - ADT7476_16

Fabricante ElectrónicoNo. de piezaDatasheetDescripción Electrónicos
logo
Analog Devices
ADT7476A AD-ADT7476A Datasheet
1Mb / 72P
   dBCool Remote Thermal Controller and Voltage Monitor
REV. 0
logo
ON Semiconductor
ADT7476A ONSEMI-ADT7476A Datasheet
613Kb / 67P
   dBCOOL Remote Thermal Controller and Voltage Monitor
May, 2010 ??Rev. 3
ADT7476A ONSEMI-ADT7476A Datasheet
541Kb / 69P
   Remote Thermal Controller and Voltage Monitor
February, 2016 ??Rev. 7
logo
Analog Devices
ADT7476AARQZ AD-ADT7476AARQZ Datasheet
1Mb / 72P
   dBCool Remote Thermal Controller and Voltage Monitor
REV. 0
logo
ON Semiconductor
ADT7476AARQZ ONSEMI-ADT7476AARQZ Datasheet
613Kb / 67P
   dBCOOL Remote Thermal Controller and Voltage Monitor
May, 2010 ??Rev. 3
More results

Descripción similar - ADT7476_16

Fabricante ElectrónicoNo. de piezaDatasheetDescripción Electrónicos
logo
ON Semiconductor
ADT7476A ONSEMI-ADT7476A_16 Datasheet
541Kb / 69P
   Remote Thermal Controller and Voltage Monitor
February, 2016 ??Rev. 7
ADT7463 ONSEMI-ADT7463_13 Datasheet
732Kb / 50P
   Remote Thermal Controller and Voltage Monitor
May, 2013 ??Rev. 7
logo
Analog Devices
ADT7476 AD-ADT7476 Datasheet
1Mb / 72P
   dBCool Remote Thermal Controller and Voltage Monitor
REV. A
ADT7468 AD-ADT7468 Datasheet
1,021Kb / 80P
   dBCool??Remote Thermal Controller and Voltage Monitor
REV. 0
logo
ON Semiconductor
ADT7476A ONSEMI-ADT7476A Datasheet
613Kb / 67P
   dBCOOL Remote Thermal Controller and Voltage Monitor
May, 2010 ??Rev. 3
ADM1027 ONSEMI-ADM1027 Datasheet
1Mb / 56P
   dBCOOL??Remote Thermal Controller and Voltage Monitor
May 2010 - Rev. 3
ADT7466 ONSEMI-ADT7466 Datasheet
691Kb / 48P
   dBCool짰 Remote Thermal Controller and Voltage Monitor
May 2010 ??Rev. 3
ADT7468 ONSEMI-ADT7468 Datasheet
1Mb / 81P
   dBCool짰 Remote Thermal Controller and Voltage Monitor
May 2010 ??Rev. 3
ADT7476 ONSEMI-ADT7476 Datasheet
620Kb / 67P
   dBCOOL Remote Thermal Controller and Voltage Monitor
May, 2010 ??Rev. 6
logo
Analog Devices
ADT7466 AD-ADT7466 Datasheet
1Mb / 48P
   dBCool Remote Thermal Controller and Voltage Monitor
REV. 0
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68


Datasheet Descarga

Go To PDF Page


Enlace URL




Política de Privacidad
ALLDATASHEET.ES
¿ALLDATASHEET es útil para Ud.?  [ DONATE ] 

Todo acerca de Alldatasheet   |   Publicidad   |   Contáctenos   |   Política de Privacidad   |   Intercambio de Enlaces   |   Lista de Fabricantes
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com