Motor de Búsqueda de Datasheet de Componentes Electrónicos |
|
BCM3814V60E15A3C02 Datasheet(PDF) 9 Page - Vicor Corporation |
|
BCM3814V60E15A3C02 Datasheet(HTML) 9 Page - Vicor Corporation |
9 / 39 page BCM® in a VIA Package Rev 1.4 vicorpower.com Page 9 of 39 09/2016 800 927.9474 BCM3814x60E15A3yzz PMBusTM Reported Characteristics Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of -40°C ≤ TCASE ≤100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted. Monitored Telemetry • The BCM communication version is not intended to be used without a Digital Supervisor. ATTRIBUTE DIGITAL SUPERVISOR PMBusTM READ COMMAND ACCURACY (RATED RANGE) FUNCTIONAL REPORTING RANGE UPDATE RATE REPORTED UNITS HI Side Voltage (88h) READ_VIN ± 5%(LL - HL) 28V to 66V 100µs VACTUAL = VREPORTED x 10-1 HI Side Current (89h) READ_IIN ± 20%(10 - 20% of FL) ± 5%(20 - 133% of FL) -1A to 44A 100µs IACTUAL = IREPORTED x 10-2 LO Side Voltage[1] (8Bh) READ_VOUT ± 5%(LL - HL) 7.0V to 16.55V 100µs VACTUAL = VREPORTED x 10-1 LO Side Current (8Ch) READ_IOUT ± 20%(10 - 20% of FL) ± 5%(20 - 133% of FL) -4A to 176A 100µs IACTUAL = IREPORTED x 10-2 LO Side Resistance (D4h) READ_ROUT ± 5%(50 - 100% of FL) at NL ± 10%(50 - 100% of FL)(LL - HL) 500µ to 3000µ 100ms RACTUAL = RREPORTED x 10-5 Temperature[2] (8Dh) READ_TEMPERATURE_1 ± 7°C(Full Range) - 55ºC to 130ºC 100ms TACTUAL = TREPORTED Variable Parameter • Factory setting of all below Thresholds and Warning limits are 100% of listed protection values. • Variables can be written only when module is disabled either EN pulled low or VHI < VHI_UVLO-. • Module must remain in a disabled mode for 3ms after any changes to the below variables allowing ample time to commit changes to EEPROM. ATTRIBUTE DIGITAL SUPERVISOR PMBusTM COMMAND [3] CONDITIONS / NOTES ACCURACY (RATED RANGE) FUNCTIONAL REPORTING RANGE DEFAULT VALUE HI Side Overvoltage Protection Limit (55h) VIN_OV_FAULT_LIMIT VHI_OVLO- is automatically 3% lower than this set point ± 5%(LL - HL) 28V to 66V 100% HI Side Overvoltage Warning Limit (57h) VIN_OV_WARN_LIMIT ± 5%(LL - HL) 28V to 66V 100% HI Side Undervoltage Protection Limit (D7h) DISABLE_FAULTS Can only be disabled to a preset default value ± 5%(LL - HL) 28V or 66V 100% HI Side Overcurrent Protection Limit (5Bh) IIN_OC_FAULT_LIMIT ± 20%(10 - 20% of FL) ± 5%(20 - 133% of FL) 0 to 44A 100% HI Side Overcurrent Warning Limit (5Dh) IIN_OC_WARN_LIMIT ± 20%(10 - 20% of FL) ± 5%(20 - 133% of FL) 0 to 44A 100% Overtemperature Protection Limit (4Fh) OT_FAULT_LIMIT Internal Temperature ± 7°C(Full Range) 0 to 125°C 100% Overtemperature Warning Limit (51h) OT_WARN_LIMIT Internal Temperature ± 7°C( Full Range) 0 to 125°C 100% Turn on Delay (60h) TON_DELAY Additional time delay to the Undervoltage Startup Delay ± 50µs 0 to 100ms 0ms [3] Refer to internal µc datasheet for complete list of supported commands. [1] Default READ LO Side Voltage returned when unit is disabled = -300V. [2] Default READ Temperature returned when unit is disabled = -273°C. |
Número de pieza similar - BCM3814V60E15A3C02 |
|
Descripción similar - BCM3814V60E15A3C02 |
|
|
Enlace URL |
Política de Privacidad |
ALLDATASHEET.ES |
¿ALLDATASHEET es útil para Ud.? [ DONATE ] |
Todo acerca de Alldatasheet | Publicidad | Contáctenos | Política de Privacidad | Intercambio de Enlaces | Lista de Fabricantes All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |